Messages 42001 - 42200

Jump to:

EDA42060 CALLITOC ERROR OCCURED, STATE IS %1%2, RC is %3%4

EDA42100 ERROR - AT keyword is required (must be PSBLIB/DBDLIB)

EDA42001 MISSING KEY FOR SEGMENT %1%2

If a segment is defined as keyed, it must be identified by key value to be updated, or an attempt may have been made to insert a keyed segment without specifying a value for the key.

EDA42002 KEY VALUE FOUND BUT SEGMENT DATA DOES NOT MATCH %1%2

A segment with the unique key value specified exists, but the data in the segment does not match additional data specified in the where clause.

EDA42003 UNIQUE KEY ALREADY EXISTS FOR SEGMENT %1%2

The unique key value specified for insertion already exists.

EDA42004 YOU CANNOT UPDATE THE KEY VALUE FOR SEGMENT %1%2

An attempt was made to update a key value. The segment must be deleted and the new value inserted.

EDA42005 SEGMENT NOT FOUND %1%2

The values specified in the where clause do not match any segment in the database.

EDA42006 MULTIPLE SEGMENTS FOUND %1%2

An attempt was made to update a non-uniquely keyed segment, but more than one segment matches the where clause values.

EDA42007 SEGMENT ALREADY EXISTS %1%2

The update of a uniquely identified, non-unique/no keyed segment would result in a duplicate segment.

EDA42008 SEGMENT IS KEY SENSITIVE ONLY %1%2

Key sensitive segments cannot be inserted or updated, and can only be deleted when they have a unique key.

EDA42009 VARIABLE LEN SEGMENTS NOT SUPPORTED %1%2

The segment was found to have a .CNT field, which is currently not supported.

EDA42010 UNABLE TO RETRIEVE SEGMENT %1%2

A segment had been identified and verified as unique, but when the interface attempted to retrieve the segment for update, the data was found to have been changed.

EDA42011 WRITE PERMISSION DENIED BY ACCESS FILE PARAMETER, WRITE=NO

To update an IMS database using SQL, the access file member must have WRITE=YES coded.

EDA42021 ERROR IN ACCESS FILE, KEYTYPE INVALID FOR SEGMENT %1%2.

The KEYTYPE parameter for the named segment is invalid. See the IMS/DB interface manual for a list of valid key types.

EDA42022 ERROR IN ACCESS FILE, TOO MANY SKY ELEMENTS %1%2%3%4.

There are more than 20 XFLD records in the Access file.

EDA42023 ERROR IN ACCESS FILE, NO ALTPCBNUMBER IN XDFLD %1%2%3%4

There is no ALTPCBNUMBER key in XLFD record.

EDA42024 ERROR IN ACCESS FILE, WRONG VALUE DEFINED IN SRCH %1%2

Field name defined in SRCH elements list is not found in the Master file definition.

EDA42025 ERROR IN ACCESS FILE, WRONG VALUE DEFINED IN BASESEG %1%2

Segment name defined in BASESEG is not found in the Master file definition.

EDA42030 RESYNC NEEDED FOR RTOK %1%2

The server requested an INIT from DBCTL. DBCTL has responded that the above recovery token is in need of re-synchronization.

EDA42031 RTOK %2 IS %4

DBCTL has been called, with the above information on the above recovery token.

EDA42040 WARNING - CHECKPOINT FAILED, CHECK PSB

A checkpoint call to IMS to free resources after FIN returned an error. Ensure that PSB contains CMPAT=YES, or remove the TERM pcb's from the FOCPSB.

EDA42041 WARNING - DBCTL NOT AVAILABLE. ATTEMPTING REMOTE ACCESS

DBCTL is not available, and the user has requested that the interface attempt to connect to IMS using a remote XMI region.

EDA42060 CALLITOC ERROR OCCURED, STATE IS %1%2, RC is %3%4

An error occurred attempting to call a transaction using ITOC. See your documentation for an explanation of the return codes.

EDA42061 FATAL ERROR IN CALLITOC

Out of memory condition occurred.

EDA42062 OTMA ERROR, CODE %1%2, REASON %3%4

EDA42100 ERROR - AT keyword is required (must be PSBLIB/DBDLIB)

Please specify the location of your DBD library and PSB Library, separated by a slash.

EDA42101 ERROR - Synonym name is required

EDA42102 ERROR - FOR keyword is required. Must be the member in PSBLIB

The CREATE SYNONYM process needs to know what PSB member is in use.

EDA42103 ERROR - FOR keyword value is a maximum of 8 bytes

The FOR keyword is used to specify the member in the PSB lib that you wish to use in the CREATE SYNONYM process. This member name can be a maximum of 8 bytes.

EDA42104 ERROR - CREATE SYNONYM process is out of memory

EDA42105 ERROR - PARMS must be supplied (Cobol FD path, SEGNAME...)

EDA42106 ERROR - PCB number %1%2 not found in PSB %3%4

The DATABASE parameter identifies which PCB number you wish to create a synonym for. However, the PSB specified in the FOR parameter does not contain that many PCBs.

EDA42107 ERROR - Load Error, unable to continue.

An error has occurred loading required support modules. Please contact your iWay representative.

EDA42108 ERROR - Cobol FD not supplied for segment %1%2

EDA42109 ERROR - Unable to create MFD for %1%2

EDA42110 ERROR - Matching segment %1%2 with fields in FD %3%4

EDA42111 ERROR - Unable to find psb in %1%2%3%4

EDA42112 ERROR - Cobol FD at %1%2 not found or in error

EDA42113 ERROR - Card number%1%2 - %3%4

EDA42114 Card image %1%2%3%4

EDA42115 FDPARM error %1%2 is invalid.

EDA42116 Segment %1%2 is not in pcb %3%4

The parameters of the CREATE SYNONYM command specified a segment that is not in the PCB. Verify that the correct psb was used.

EDA42117 ERROR synonym already exists for %1%2

EDA42118 WARNING - Could not find a position for IMS field %1%2

In order for an IMS field to be attached to a field in the FD, it must match both the length and offset of the FD field. This may happen when there are redefines in the FD that have been mapped to a separate segment in the Master.

EDA42119 Invalid PCB structure found in PCB %1%2, segment %3%4

The PCB that was selected to create the synonym could not be parsed. This may happen if the DBDGEN for a PCB was incorrect or if the DBDLIB specified was incorrect.

EDA42120 ERROR when writing resulting Master File.

EDA42126 IMSYN PSB: error allocating to dd DDPSBLIB

EDA42127 IMSYN PSB: error allocating to dd DDDBDLIB

EDA42128 IMSYN PSB: error allocating DDOUTDSN

EDA42129 IMSYN PSB: error opening PSB/DBD file

EDA42130 IMSYN PSB: error opening output file

EDA42131 IMSYN PSB: error with the parms

EDA42132 IMSYN PSB: error loading PSB %1

EDA42133 IMSYN PSB: error loading DBD %1

EDA42134 IMSYN PSB: error returning from autoimsc

EDA42135 IMSYN PSB: error (re)opening CONSIMS FOCTEMP

EDA42136 IMSYN PSB: error freeing DDOUTDSN

EDA42137 IMSYN PSB: error writing CONSIMS FOCTEMP

EDA42138 IMSYN PSB: error loading PSB = %1 - no DB PCB in PSB

EDA42139 IMSYN PSB: error in PSB %1 - PCB Number %2 Has no SenSegs

EDA42140 IMSYN PSB: error in DBD %1 - there is no SenSeg Name %2

EDA42141 IMSYN PSB: error - Segment %1 is Key Sensitive but no key

EDA42142 IMSYN PSB: error - Wrong Pcb # %1; # of Pcb's in PSB: %2

EDA42143 IMSYN PSB: error - Could not get Pcb number %1

EDA42144 IMSYN PSB: error - No Target Segment for SenSeg %1

EDA42145 IMSYN PSB: error - No XDFLD for seq Index %1

EDA42146 IMSYN PSB: error - Not an Index Relationship Index DBD %1

EDA42147 IMSYN PSB: error - No Source Segment Found

EDA42148 IMSYN PSB: error - No Search Fields for Source Segment


iWay Software