Messages 35801 - 36000
EDA35801 EDAINIT FAILURE, POSSIBLE BAD COMM CONFIG FILE (RC = %1)
The EDA/API cannot be initialized. Possible problems include a bad or missing communications configuration file. Check the EDATRACE and resolve the problem before continuing.
EDA35802 FAILURE TO READ EDA SERVER LIST CORRECTLY
Failed to obtain a list of valid servers due to a failed EDAAPI call. Check EDATRACE and resolve the problem before continuing.
EDA35803 NO EDA SERVERS AVAILABLE
Failed to obtain a list of valid servers. The server count returned by EDAAPI is zero. Check server configuration file and EDATRACE and resolve the problem before continuing.
EDA35804 BAD STATUS CODE (%1) RECEIVED FROM SERVER %2
An invalid status was reported by the EDA/API on attempting an operation with an SCB connected (or connecting) to this server. Check EDATRACE for more detail.
EDA35805 - EDA32850 reserved for edxfoc %1%2%3%4
EDA35851 EDA STATUS (-1): INVALID CONTEXT
The EDA/API returned a bad Status Code of -1, meaning the supplied EDA ID was invalid.
EDA35852 EDA STATUS (-2): TOO MANY EDA CONTEXTS
The EDA/API returned a bad Status Code of -2, meaning too many contexts were requested (EDAINIT).
EDA35853 EDA STATUS (-3): INVALID SID
The EDA/API returned a bad Status Code of -3, meaning the supplied SCB Identifier was invalid.
EDA35854 EDA STATUS (-4): TOO MANY SCBS ALLOCATED
The EDA/API returned a bad Status Code of -4, meaning too many SCBs were requested (EDACONNECT).
EDA35855 EDA STATUS (-5): THE SCB IS NOT INITIALIZED
The EDA/API returned a bad Status Code of -5, meaning the SCB being used has not yet been EDACONNECTed.
EDA35856 EDA STATUS (-6): THE SCB IS ALREADY INITIALIZED
The EDA/API returned a bad Status Code of -6, meaning the SCB being passed to EDACONNECT is already in a connected state.
EDA35857 EDA STATUS (-7): CANNOT INITIALIZE EDALINK
The EDA/API returned a bad Status Code of -7, meaning a failure has occurred within the communications subsystem at startup time.
EDA35858 EDA STATUS (-8): CANNOT CLOSE DOWN EDALINK
The EDA/API returned a bad Status Code of -8, meaning a failure has occurred within the communications subsystem at termination time.
EDA35859 EDA STATUS (-9): ERROR CONNECTING TO SERVER
The EDA/API returned a bad Status Code of -9, meaning a connection to the specified server is currently impossible.
EDA35860 EDA STATUS (-10): ERROR DISCONNECTING FROM SERVER
The EDA/API returned a bad Status Code of -10, meaning an error has occurred while disconnecting from the current server.
EDA35861 EDA STATUS (-11): ERROR SENDING DATA TO SERVER
The EDA/API returned a bad Status Code of -11, meaning an error has occurred while shipping information to the server (the server is probably down).
EDA35862 EDA STATUS (-12): ERROR RECEIVING DATA FROM SERVER
The EDA/API returned a bad Status Code of -12, meaning an error has occurred while receiving data from the server (the server is probably down).
EDA35863 EDA STATUS (-13): INVALID OPERATION
The EDA/API returned a bad Status Code of -13, meaning an EDA/API call has been made which is either not supported on the specified server, or is not valid in the current state.
EDA35864 EDA STATUS (-14): INSUFFICIENT MEMORY
The EDA/API returned a bad Status Code of -14, meaning the EDA/API has issued a request for dynamic memory which has failed. Try to run this program in a larger region.
EDA35865 EDA STATUS (-15): INVALID PARAMETER VALUE
The EDA/API returned a bad Status Code of -15, meaning a supplied value is out of the range allowed for it.
EDA35866 EDA STATUS (-16): MISALIGNED TUPLE
The EDA/API returned a bad Status Code of -16, meaning an alignment problem has occurred on an EDAFIELD or EDAFETCH call.
EDA35867 EDA STATUS (-17): INVALID USERID OR PASSWORD ACCESS DENIED
The EDA/API returned a bad Status Code of -17, meaning the supplied UserID or PassWord is invalid (or not supplied).
EDA35868 EDA STATUS (-18): INTERNAL API ERROR
The EDA/API returned a bad Status Code of -18; an internal error has occurred. Please contact Information Builders about the problem.
EDA35869 EDA STATUS (-19): UNAVAILABLE FUNCTION
The EDA/API returned a bad Status Code of -19, meaning the requested function is not available in this release of the EDA/API or Server.
EDA35870 EDA STATUS (-20): PASSWORD EXPIRED
The EDA/API returned a bad Status Code of -20, meaning the current PassWord (for the EDACONNECT) has expired. Change it and retry your application.
EDA35871 EDA STATUS (-21): INVALID NEW PASSWORD
The EDA/API returned a bad Status Code of -21, meaning the current PassWord (for the EDACONNECT) has expired. Change it and retry your application.
EDA35872 EDA STATUS (-22): ENCRYPTION VERSION MISMATCH
The EDA/API returned a bad Status Code of -22, meaning the Client and Server has a mismatch in encryption algorithms.
EDA35873 EDA STATUS (-23): CONNECTION NO LONGER VALID
The EDA/API returned a bad Status Code of -23, meaning the Server connection has been lost (probably internally). Retry.
EDA35874 - EDA36000 reserved for edxfoc %1%2%3%4