This section lists the data definitions that make up the SiteAnalyzer and SmartMode administrative databases and provides an explanation of the column values.
MVS name: MASTER.DATA(SMCNTRL)
VM name: SMCNTRL MASTER
Keeps track of which data sources are monitored, governed and have rules applied. This is the main monitoring and governing control database. It is updated every time the administrator either turns on or off collection for either Global Monitoring or individual object monitoring or governing.
Column |
Value |
Description |
SMSERVER |
Alphanumeric, length=48 |
SMSERVER is the name used during the configuration process. |
SMNAME |
Alphanumeric, length=66 |
The SMNAME can be used for relational or non-relational data types. If it contains a relational database name, it must be fully qualified. For example, there are three identifiers contained in a complete name: 'LOCATION.CREATOR.TABLE' |
SMSOURCE |
Alphanumeric, length=8 |
The data type can be a DBMS accessed via SQL passthru, such as DB2; or the data type can be EDA, indicating that a server has access to the data type listed in its catalog. See your FOCUS manual for a list of valid engine names. |
SMSUFFIX |
Alphanumeric, length=12 |
This is the data source suffix. Note: This column is not used in this release. To be used in a future release. |
SMKNBNAME |
Alphanumeric, length=8 |
The rule file name used for governing. |
SMCOLLECT |
Alphanumeric, length=1 |
Indicates whether SiteAnalyzer and SmartMode should record Usage Monitor data about any request using SMTBNAME. 0= Off 1= On |
SMGOVERN |
Alphanumeric, length=1 |
Indicates whether SiteAnalyzer and SmartMode should govern any request using SMTBNAME. 0= Off 1= On |
SMADVISE |
Alphanumeric, length=1 |
Indicates whether SiteAnalyzer and SmartMode should advise on canceling any request using SMTBNAME. 0= Off 1= On |
Information Builders |